companydirectorylist.com  Global Business Directories og selskapets kataloger
Søk Business, Company, Industri :


Country Lister
USA selskap Kataloger
Canada foretak Lister
Australia Business Kataloger
Frankrike Selskapets Lister
Italia Selskapets Lister
Spania Firma Kataloger
Sveits foretak Lister
Østerrike Selskapets Kataloger
Belgia virksomhet kataloger
Hong Kong Selskapets lister
Kina Business Lister
Taiwan Selskapets Lister
De forente arabiske emirater selskapets kataloger


industri Kataloger
USA Industri Kataloger














  • Step from garage into House?? - The Building Code Forum
    I do not see anywhere in the IRC 2015 that requires a step from the garage into the house I saw the opening penetrations R302 5 Garage section R309 Is the step still a requirement and if so is there a minimum dimension?
  • NC Garage Legal Finish Requirement | The Building Code Forum
    The garage is 100% residential- not a business The first floor has lights outlets, the second floor only has a preexisting light fixture (exterior light) from the original house and no added wiring
  • Equipment Bollard in a Residential Garage - The Building Code Forum
    Re: Equipment Bollard in a Residential Garage We have a minimum 36 inch high 2" schedule 40 iron pipe embedded in the garage slab We also have two alternates that are wheel stops and pipes bolted to the floor for retrofits 99% of the time we see the schedule 40 pipe embedded in the concrete
  • fire separation in garages - The Building Code Forum
    When constructing split entry's, we alway's framed around the steel I-beam and post in the garage, installed gyp and taped the seams Same on the fur-down (duct covering)and ceiling gyp, just tape unless spray texure was being installed, alway's thought that was the code are we requiring something different now?
  • Minimum Floor Slope for Drainage - The Building Code Forum
    Irc The building code requires that a garage floor be sloped towards the door, but does not specify a minimum slope It is usually 1 8” to 1 4” per foot Here is the citation from the International Residential Code (IRC): R309 4: "The area of floor used for parking of automobiles or other vehicles shall be sloped to facilitate the movement of liquids to a drain or toward the main vehicle
  • 2024 Portal Frames | The Building Code Forum
    In the picture provided, I would say that is still a single portal frame opening I think the intent was to prevent two portal frames immediately adjacent to each other using a common header Example would be at the garage, where for example, multiple garage door openings are on the same wall plane and configured to use a common header over 2+ portal frames - that would be prohibited
  • Habitable Space Exiting into a Garage | The Building Code Forum
    The habitable space only accessed through the garage is a private hair salon, I believe this would be considered habitable space? The other rooms only accessed through the garage are a laundry room, a toilet room and a storage room, all considered non-habitable
  • Garage Floor Drain - The Building Code Forum
    Needing some info on garage floor drain Have read codes that garage floor must slope out or to a drain Have new residential construction with attached garage The builder installed what he identifies as floor drain I drained the livewell from my boat in garage floor Floor is completely




Virksomhet kataloger , Company Kataloger
Virksomhet kataloger , Company Kataloger copyright ©2005-2012 
disclaimer